Screw Compressor Common Fault Guide


Classification: Compressor Guide

Classification: Maintenance process

Classification: Technical Data

Time:2017-09-27 08:58

Failure phenomenon: the exhaust temperature of the unit is high (over 100°C) and the coolant level of the unit is too low (it should be seen from the oil sight glass, but not more than half); Dirty oil cooler; The oil filter core is blocked; Temperature control valve failure (component failure); The oil cut-off solenoid valve is not powered or the coil is damaged; The diaphragm of the oil cut-off solenoid valve is broken or aged; Fan motor failure; Cooling fan damage; the exhaust pipe is not unblocked or the exhaust resistance (back pressure) is large; The ambient temperature exceeds the specified range (38G or 46 min); Temperature sensor failure (Intellisys control
Fault phenomenon: unit exhaust temperature is high (more than 100°C)
  • The coolant level of the unit is too low (it should be seen from the oil sight glass, but not more than half);
  • Dirty oil cooler;
  • The oil filter core is blocked;
  • Temperature control valve failure (component failure);
  • The oil cut-off solenoid valve is not energized or the coil is damaged;
  • Oil-cut solenoid valve diaphragm rupture or aging;
  • Fan motor fault;
  • The cooling fan is damaged;
  • The exhaust pipe is not smooth or the exhaust resistance (back pressure) is large;
  • The ambient temperature exceeds the specified range (38mm or 46mm);
  • Temperature sensor fault (Intellisys control unit);
  • Whether the pressure gauge is faulty (relay control unit).
Fault phenomenon: large oil consumption of the unit or large oil content of compressed air
 
  • Too much cooling dose;
  • The oil return pipe is blocked;
  • The installation of the oil return pipe (the distance from the bottom of the oil separation core) does not meet the requirements;
  • The pressure of the unit is too low;
  • The oil separation core is broken;
  • The unit has oil leakage;
  • Deterioration or extended use of coolant.
   
Fault phenomenon: unit pressure is low
   
  • The actual gas consumption is larger than the output gas of the unit;
  • Bleed valve fault (cannot be closed when loaded);
  • Intake valve fault;
  • Failure of hydraulic cylinder;
  • Load solenoid valve (1SV) fault
  • The minimum pressure valve is stuck;
  • There is leakage in the user pipe network;
  • Pressure setting too low;
  • Pressure sensor fault (Intellisys control unit);
  • Pressure gauge fault (relay control unit);
  • Pressure switch fault (relay control unit);
  • Pressure sensor or pressure gauge input hose leaks;
   
Fault phenomenon: unit exhaust pressure is too high
   
  • Intake valve fault;
  • Failure of hydraulic cylinder;
  • Load solenoid valve (1SV) fault;
  • Pressure setting too high;
  • Pressure sensor fault (Intellisys control unit);
  • Pressure gauge fault (relay control unit);
  • Pressure switch fault (relay control unit).
   
Fault phenomenon: large unit current
  • The voltage is too low;
  • Loose wiring;
  • The pressure of the unit exceeds the rated pressure;
  • The oil separation core is blocked;
  • Fault of contactor;
  • Host fault;
  • Main motor fault;
   

Fault phenomenon: the unit cannot start

   
  • The fuse is damaged;
  • The temperature switch is damaged;
  • Loosen the wiring;
  • Main motor thermal relay acts;
  • The thermal relay of the fan motor operates;
  • The transformer is broken;
  • Intellisys without power input (Intellisys control unit);
  • Fault not eliminated (Intellisys control unit);
  • Intellisys controller fault.
   
Fault phenomenon: large current or trip when the unit starts
   
  • User air switch problem;
  • The input voltage is too low;
  • Star-delta conversion interval is too short (should be 10~12 seconds);
  • Hydraulic cylinder fault (not reset);
  • Intake valve fault (too large opening degree or stuck);
  • Loose wiring;
  • Host fault;
  • Main motor fault;
  • 1TR time relay is broken (relay control unit).